Q. The boiler will not produce heat

A. Check the Red Power Symbol is illuminated on the boiler display, Press the On/Off button to illuminate the Red Power Symbol. Check the external controls are calling for Heat, TC should be illuminated on the boiler display next to the Red Power Symbol.

digital screen

Q. The Power symbol and TC are illuminated, the boiler will not produce heat.

Check the boilers in-built timer has been deactivated. See the Installation manual for more details.
Check the target temperature is higher than the actual temperature.
Adjust the hysteresis to a lower setting to activate the boiler. See the installation manual for more details.

Q. The touch screen is not responding.

A. Make sure the screen has not been locked. Press and hold the Confirm button for 5 seconds to lock or unlock the screen. Isolate the power supply to the boiler for 30 seconds. Re-introduce the power and check the screen for correct operation.

digital screen showing child lock

Q. The boiler display shows F1.

A. F1 indicates the boiler has over heated and activated the over temperature safety thermostat. Please contact your installer or local engineer.

digital screen showing F1 error

Q. The boiler display shows F6.

A. F6 indicates insufficient water flow around the heating system. Usually due to air in the system or a poorly designed heating system.
Check to make sure the system has an auto by-pass valve. Contact your installer if unsure.

digital screen showing F6 error

Q. Boiler Display is Flashing

A. Long Press the On/Off key to stop the screen from Flashing